8. Insert the top of the check valve into the upper air tube.
NOTE: Insert the check valve into the air tube so that
the arrow on the valve points toward the gun.
G U
9. If the lower air tube is too long, trim the tube so that it fits
the gun.
10. Push the lower air tube onto the bottom of the check
valve.
NOTE: Make sure to attach the shorter air tube to the
gun fitting and the longer air tube to the cup lid
air nipple.

Replacing the Cup Gasket

The cup gasket must be replaced periodically due to normal
wear. It is important to inspect the cup gasket during each
cleaning.
1. Release the cup locking lever.
2. Hold the cup and twist the spray gun in the direction
indicated by the arrows on the bridge.
3. Lift the spray gun away from the cup.
4. Pull the worn cup gasket out of the lid.
5. Press a new cup gasket into the lid.
6. Place the spray gun onto the top of the cup.
Bridge
Cup Gasket
7. Turn the spray gun opposite the direction indicated by the
arrows on the bridge until the pegs on the cup are in the
notches of the bridge.
8. Tighten the cup locking lever.
© SprayTECH. All rights reserved.
Valve Seal
Air Tube
Check Valve
Air Tube
Cup Locking
Lever
Swivel Lever
Lid
Converting to a Single Pin
Trigger
The trigger on your HVLP spray gun can be converted to a
single pin setup for a softer pull. Trigger pull is reduced by
removing the upper trigger pin and operating the gun with only
the lower trigger pin in place. This setup reduces finger
fatigue and provides greater control when spraying thin, light
viscosity materials such as stains, varnishes, and sealers.
1. Remove the retaining clip on the upper trigger pin by
placing the flat edge of a screwdriver between the clip and
the pin and gently prying it off.
2. Pull the trigger pin out from the opposite side of the gun.

Using a Pressure Feed System

To increase spray time between material refills, your HVLP
spray gun can be connected to a larger material pressure pot
and air compressor.

Converting the Gun to Pressure Feed

Before using a pressure feed system, the spray gun must be
converted to a pressure fed gun.
1. Loosen the retaining nut using a wrench and remove the
one quart cup assembly.
2. Pull the air tube off of the air tube fitting on the spray gun.
3. Remove the air tube fitting using a wrench.
4. Thread the set screw into the air tube fitting location and
tighten into place.
Air Tube Fitting
7
Air Tube
Retaining Nut
Cup Assembly
Set Screw