TZS First AUSTRIA FA-6408 Mode D'emploi page 2

Balance de cuisine électronique
Table des Matières

Publicité

1
N
2
3
i
4
a
5
a
b
d
6
7
8
M_6408_v02.indd 2-3
instrUction MAnUAl
instrUction
please read this instruction carefully in order to use the scale correctly & keep the scale in good
condition.
FEAtUrEs AnD sPEciFicAtions
1. default real time clockindication when idle
2. alarm timer setting, ambient temperature sensor/indication
3. Measuring fluid volume vs weight for milk, water.
4. g (kg)/lb:oz convertible indication.
5. Low battery power (Lo)/Overload indication (Err)
6. using high precision strain gauge sensor
7. Zero/tarefunction
8. two operation modes Mounting on wall or putting on platform
oUtlinE
(see fig. 1)
1. lcd display
2. glass weighing platform
3. (folded)
AccEssorY
1. screw x 2
2. plastic anchor x 2
to instAll thE scAlE
1. the distance between 2 screws is 87.7mm
b
c
2. Find the position on wall where to mount the scale. use a pencil to mark position of 2 nail
holes with 87.7mm distance.
3. drill 2 nail holes on the marks.
4. Insert the 2 provided plastic anchors to the nail holes till they are jammed tight inside the nail
holes. Then drive 2 screws, one at a time, to the anchors into the wall. Ensure the screws
fixed securely.
5. Now mount the scale by fitting the 2 holes on the back side of scale to the 2 screws. Once
fitted, pull the scale downwards to ensure the scale is well mounted. To dismantle, simply pull
the scale upwards.
lcD DisPlAY
1. timer
2. alarm
3. tare
4. Negative Value
5. Zero
working MoDEs
kEY illUstAtion
1. alarm timer setting.
2. Down/Unit conversion
3. switch
4. up/Zero or tare
4. (unfolded)
7. Bowl
5. battery case cover
8. (back view)
6. holes
9. (side view)
(see fig. 2)
(see fig. 3)
6. room temperature
11. Water volume indicator
7. temperature in °c or °F
12. Milk volume indicator
8. aM real time clock display
13. Fluid volume
9. Weight in kg. or lb:oz
10. pM real time clock display
2
to instAll BAttErY
1. Battery
2x3V lithium cells. Please remove isolation sheet before use.
2. to replace battery
A. Open battery case cover on the back of scale.
B. Bend the small contact outwards and the battery will come out.
c. install new battery by putting one side of battery beneath the black tab and then pressing
down the other side until the battery is locked.
D. Close the battery case cover.
to sEt tiME
(see fig. 4)
1. Install battery and enter time setting mode automatically. When hour display is flashing,
press pq to set hour. please mind aM/pM selection during setting.
2. Press „T-SET" to confirm and prompt to minute setting. When minute display is flashing,
press pq to set minute.
3. Press „T-SET" to finish time setting.
remark:
1. Press „ON/OFFW to cancel time setting.
2. return to real time display after idling for 60 seconds.
to rE-sEt tiME
(see fig. 5)
Under real time display mode, press „T-SET" for 3 seconds to enter time setting mode.
to convErt Unit sYstEMs
1. Applicable only when the scale is available in indication of Metric (g, kg) & Imperial (oz, Ib).
Press button ʻUnit' for 3 seconds, to convert between ʻg, kg' & ʻoz, Ib' indication anytime or
during course of weighing. (see fig. 6)
2. Press button „Unit" momentarily, to convert & cycle through measuring modes of : Weight-
Volume fluid of water-Volume fluid of milk. (see fig. 7)
a = Metic system, B = imperial system
remark: the unit system of scale depends on sales destination or the requirement of
distributor.
tEMPErAtUrE sEnsor
1. current temperature is shown at the higher right corner of lcd.
2. temperature range: 0~+40°c
3. Division: 0.5°C
Note: Temperature indication in °C or °F is preset before ex-factory & can not change.
MoDE convErsion
(see fig. 8)
oPErAtion
two operation modes: Mounting on wall or putting on platform
wEighing MoDE (see fig. 9)
1. When weighing platform is folded
2. pull down the weighing platform to horizontal position. scale will enter weighing mode
automatically.
3. Place weighing object on the glass platform. LCD will display the weight reading. If bowl is
used, put the bowl on the glass platform, and press Z/T button to reset LCD reading to „0"
before loading weighing object on the bowl. If the weighing object is water or milk, press
UNIT button to choose volume mode to view the volume of weighing object.
4. Fold the weighing platform or press on/oFF button to exit weighing mode lcd will return to
displaying default real time clock.
3
12-11-29 下午4:26

Publicité

Table des Matières
loading

Table des Matières