TECHNICAL SPECIFICATIONS
Power
230V AC +/- 10%
Max. Power consumption
0.5A (230v) 65mA(12V) 80mA(24V)
Outputs:
Fixed outputs
2 Relay 1A/30V
Available codes
2.097.152.281 Millions
Encryption technology
Hopping code
Key Encryption
64 bits
Detection of errors during transmission
2 CRC bits
Error detection
31/255/1000 different codes
Number of codes
Self learning
Fuction selection:
1 relay
Memorizes in function of the code
2 relays or more
Predeterminated function or program
Latch relays
Position 1 programable
Frecuency
433.92MHz OR 868,35MHz
Certificates
ETS300-220/ETS300-683
Spurious emissions
< -57dBm
Sensitivity
< -104dBm
Range
60m
Access control
YES
Temperature
0 to 70º
Antenna
17cm / 8,5cm
WARNING!!
Instruction Manual
- Smart control product range, intelligent code, safe, reliable and cannot be copied.
- Receiver for any automatic system.
- Multy function selection.
- Option to use Smart transmitters with Hopping Code or fixed code.
OPTIONS SELECTOR
OPTION 1 - Option function relays / Predetermined functions
ON
This assigns the function (Button) to activate the relays according to the order of memorization of the first two codes.
The function (button) of the 1st memorized code is assigned to the 1st relay.
The function (button) of the 2nd memorized code is assigned to the 2nd relay.
OFF
Default relays
Function (button) 1, first relay.
Function (button) 2, second relay.
OPTION 2 - Hopping Code / fixed code
ON
Hopping Code
OFF
ixed code
F
OPTION 3 - Multi- Memorization / manual memorization
ON
Memorization systems available, a), b) y c) (see below)
OFF
Allows for manual memorization system a), and special functions system c) (see below)
OPTION 4 - Multi- Relay 1 Latch/ Relay 1 Pulse
ON
Relay 1 Latch mode.
Activated – Deactivated – Activated ..., according to signal
OFF
Relay 1 Pulse mode.
Relay maintains activated during signal reception (Deadman)
Note 1:
If transmitters Smart with Hopping Code are used (Dip 2 in ON position), all the transmitters will have a different code.
If transmitters Smart with fixed code are used (Dip 2 in OFF position), you can use the same code for different transmitters. E.G You can assign a code for
a parking having 31/255/1000 different parking lots, or the same code for all the parking using unlimited transmitters which are the same in each
installation.
TERMINAL CONNECTIONS
POWER SUPPLY
1 2
220V
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT,MUST BE INSTALLED FOR SYSTEMS THAT ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF
(SMR 220 C2)
RELAY1 OUTPUT
4 5 6
C1
Common relay 1
NC1 Normally closed contact
NO1 Normally open contact
RELAY
.
RELAY2 OUTPUT
7 8 9
C1
Common relay 2
NC2 Normally closed contact
NO2 Normally open contact
RELAY