d. DC Current
Range
2mA
20mA
200mA
10A
Overload Protection: F 0.2A fuse (20A-range is not protected by a fuse)
Max. Input Current: 20A, 15 sec.
e. AC Current
Range
20mA
200mA
10A
Overload Protection: F 0.2A fuse (20A-range is not protected by a fuse)
Frequency Range: 40 to 400Hz
Max. Input Current: 20A, 15 sec.
f. Resistance
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
200MΩ
g. Capacitance
Range
2000pF
20nF
200nF
2µ F
20µ F
h. Temperature
Range
Temperature Range
T
Using a K-type thermocouple probe
DVM891_v2
Resolution
1µ A
10µ A
100µ A
10mA
Resolution
10µ A
100µ A
10mA
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
100kΩ
Resolution
1pF
10pF
100pF
1nF
10nF
- 50°C to 400°C
400°C to 1000°C
0°C to 40°C
± 0.8% of rdg ± 1 digit
± 1.2% of rdg ± 1 digit
± 2.0% of rdg ± 5 digits
± 1.2% of rdg ± 3 digits
± 2.0% of rdg ± 3 digits
± 3.0% of rdg ± 7 digits
± 0.8% of rdg ± 3 digits
± 0.8% of rdg ± 1 digit
± 5% of rdg ± 10 digits
± 2.5% of rdg ± 5 digits
Resolution
1°C
Using the built-in temperature sensor
- 8 -
Accuracy
Accuracy
Accuracy
± 1% of rdg ± 2 digits
Accuracy
Accuracy
± 0.75% of rdg ± 3°C
± 1.5% of rdg ± 15°C
± 2°C