Storage; Electrical Connection; Disposal And Recycling - Dexter power 3901316953 Traduction Des Instructions D'origine

Scie de table
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: carbon brush, table inlay, push rod, saw
blade
* Not necessarily included in the scope of delivery!

13. Storage

Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
When the sawblade and key are not in use, they can
be stored as in figure 23.
Store the operating manual with the electrical tool.

14. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavourable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is intended for use only on premises
which have a mains continuous current rating of
at least 100 A per phase and are supplied by a
distribution network with a rated voltage of 230V.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish
to operate the product meets the specified re-
quirements.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate

15. Disposal and recycling

The equipment is supplied in packaging to prevent it
from being damaged in transit.
This packaging is raw material and can thus be used
again or can be reintegrated into the raw material cy-
cle.
The device and its accessories are made of different
materials, such as metals and plastics.
Take defective components to special waste disposal
sites.
Check with your specialist dealer or municipal admin-
istration!
GB | 35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ts100s

Table des Matières