MyPool | pH · ORP
9. ALARMS
Alarm
Level
Measure out of
range
OFA Alarm
(time >OFA time)
Flow Rate
Calibration
Function
System Error
Modbus Error
To restore the default parameters, follow the steps below:
Power off the MyPool unit
Keep
and
The unit will flash
Press
Press
to restore the default parameters.
Default Parameters
Language
Time OFA
Flow Input
Set Point value
Calibration
Dosing Method
0000138876
Display MyPool pH
(<5 pH)
(>9pH)
pressed and power on the unit
rev. 1.3
Display MyPool ORP
(<100 mV)
MyPool pH
7.4 pH
7 pH / 9 pH (2-point)
Acid
EN
Actions to do
- Restore Product tank
- Replace or check the
measure probe
- Restore pH / ORP measure
- Push
to reset
- Restore Flow Rate
- Restore Probe or Buffer
solution and repeat
calibration procedure
- Press
to restore Default
parameter
- Broken Unit
- Press
to reset
- Restore communication
MyPool ORP
ES
OFF
OFF
700 mV
475 mV