GB
DISMANtLING AND ASSEMBLY
DISMANtLING
1 Front cover (5): Press on the top right and left-
hand corners of the cover (5) to release the
locking mechanism . Then slide up the cover
(5) to remove .
2 Prefilter (7): Open the catches in the direction
shown in Fig. 4 to remove the prefilter (7) .
3 Main filter (8): Grasp the two straps at the top
to pull out the filter (8) .
4 UV tubes (9): Carefully rotate the tubes (9)
either clockwise or anticlockwise until the
connections can be seen through the open-
ings of the holders . Now remove the tubes (9)
from their holders . Only grasp the tubes (9)
by the ceramic endpieces and wear gloves to
do so .
Fig. 4: Dismantling
Fig. 5: Assembly
18
ASSEMBLY
1 UV tubes (9): Carefully fit the tubes (9) into
their holders . Gently rotate the tubes (9) either
clockwise or anticlockwise until the connec-
tions audibly engage . Only grasp the tubes (9)
by the ceramic endpieces and wear gloves to
do so .
2 Main filter (8): First position the main filter (8)
at the bottom of the housing and then press
into the housing . The word "HEPA" (on white
side of filter) must face outwards .
3 Prefilter (7): Insert the filter (7) and turn the
catches in the direction shown in Fig. 5 to
secure the prefilter (7) .
4 Front cover (5): First position the bottom
holders in the openings of the housing . Secure
the cover (5) by pressing on the top right and
left-hand corners (5) until the cover audibly
engages .
tROUBLESHOOtING
Problem
Reason
Appliance is not functioning
Power plug is not
properly inserted in socket .
Front cover is not secured .
No power supply from socket .
Appliance does not respond
Batteries are failing .
to remote control unit
Batteries without contact .
Appliance is running but not
Objects are blocking
emitting air
air supply or exhaust;
protective foil has not been
removed .
Expected air purification
Appliance is standing in a
effect is absent
room with poor ventilation or
is blocked by other objects .
Filters are contaminated with
smoke and dust .
The air quality indicator
Sensors in appliance are
shows air quality constantly
contaminated .
worsening while the per-
formance level of the air
purifier keeps increasing
If the solutions suggested here still do not eliminate the problem, please contact Bielmeier Hausgeräte
GmbH or your nearest service centre .
Never try to repair the air purifier yourself!
tECHNICAL DEtAILS
Supply voltage:
220 – 240 V ~ / 50 Hz
Power consumption:
123 W
Airflow (max . ) :
500 m³ / h
Timer:
1 – 12 hours
Dimensions (H x W x D):
555 x 445 x 210 mm
GB
Solution
Check power plug .
Secure cover .
Check your
fuse box .
Replace batteries .
Check that batteries are
touching the contact springs .
Remove objects / protective foil .
Contact Bielmeier Hausgeräte
GmbH if problem persists .
Check that air can circulate
around the appliance .
Clean or replace filters .
Clean the sensor openings
with the vacuum cleaner .
CARING FOR tHE ENVIRONMENt
Do not simply throw away packaging and disused
appliances . These can be recycled .
Contact your local authority for details of the rel-
evant recycling centre or the nearest collection
point .