Autres composants
FR
Paramètre
Valve
Probe S1
Main control
Probe S2
Auxiliary control
Probe S3
Relay configuration
Probe S4
DI2 configuration
Variable 1 on display
Variable 2 on display
S1 probe alarm manag.
S2 probe alarm manag.
S3 probe alarm manag.
S4 probe alarm manag.
Unit of measure
DI1 configuration
Language
Auxiliary refrigerant
S1 calibration offset
S1 calibrat gain, 4 to 20 mA
S1 pressure: MINIMUM value
S1 pressure: MAXIMUM value 30
S1 pressure: MINIMUM alarm
value
S1 pressure: MAXIMUM
alarm value
S2 calibration offset
S2 calibrat gain, 0 to 10 mA
S2 temperature: MINIMUM
alarm value
S2 temperature: MAXIMUM
alarm value
S3 calibration offset
S3 calibration gain, 4 to 20 mA 1
S3 pressure: MINIMUM value
S3 pressure: MAXIMUM value 30
S3 pressure: MINIMUM alarm
value
S3 pressure: MAXIMUM
alarm value
S4 calibrat. offset
S4 temperature: MINIMUM
alarm value
Les données contenues dans le présent manuel ne sont pas contractuelles et peuvent être modifiées par le constructeur sans obligation de préavis. Reproduction interdite
Def.
CAREL E
X
V
12= 0 to 30 barg
6= chiller with plate heat
exchanger
1= CAREL NTC
1= Disabled
12= 0 to 30 barg
2= Alarm relay (open when
alarm active)
1= CAREL NTC
5= Regulation start/stop
5= Superheat
1= Valve opening
2= Forced valve closing
2= Forced valve closing
2= Forced valve closing
2= Forced valve closing
1= °C/K/barg;
5= Regulation start/stop
Language: English
0= same as main regulation
PROBES
0
1
0
-1
50
0
1
-50
105
0
0
-1
50
0
-50
Min.
Max.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-60 (-870), -60
60 (870), 60
-20
20
S1 press.: MAX.
-20 (-290)
value
S1 press.: MIN.
200 (2900)
value
S1 press.: MAX.
-20 (-290)
alarm value
S1 press.: MIN.
200 (2900)
alarm value
-20 (-36), -20
20 (36), 20
-20
20
S2 temp.: MAX.
-60
alarm value
S2 temp.: MIN.
200 (392)
alarm value
-60 (-870)
60 (870)
-20
20
S3 press.: MAX.
-20 (-290)
value
S3 press.: MIN.
200 (2900)
value
S3 press.: MAX.
-20 (-290)
alarm value
S3 press.: MIN.
200 (2900)
alarm value
-20 (-36)
20 (36)
S4 temp.: MAX.
-60 (-76)
alarm value
UDM
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
°C (K), barg
-
-
-
barg (psig) mA
-
barg (psig)
barg (psig)
barg (psig)
barg (psig)
°C (°F), volt
-
°C (°F)
°C (°F)
barg (psig)
-
barg (psig)
barg (psig)
barg (psig)
barg (psig)
°C (°F)
°C (°F)
GL T 120÷360