Installation And Preparation For Use; Instructions For The Installer; Installation Of The Appliances - VESTEL VEH14016-1 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. INSTALLATION AND
PREPARATION FOR USE
WARNING : This appliance must be
installed by an authorised service
person or qualified technician, according to
the instructions in this guide and in
compliance with the current local
regulations.
Incorrect installation may cause harm
and damage, for which the manufacturer
accepts no responsibility and the
warranty will not be valid.
Prior to installation, ensure that the local
distribution conditions (electricity voltage
and frequency) and the adjustments
of the appliance are compatible. The
adjustment conditions for this appliance
are stated on the label.
The laws, ordinances, directives and
standards in force in the country of use
are to be followed (safety regulations,
proper recycling in accordance with the
regulations, etc.).

2.1 Instructions for the Installer

General instructions
After removing the packaging material
from the appliance and its accessories,
ensure that the appliance is not
damaged. If you suspect any damage,
do not use it and contact an authorised
service person or qualified technician
immediately.
Make sure that there are no flammable
or combustible materials in the close
vicinity, such as curtains, oil, cloth etc.
which may catch fire.
The worktop and furniture surrounding
the appliance must be made of
materials resistant to temperatures
above 100°C.
If a cooker hood or cupboard is to be
installed above the appliance, the safety
distance between cooktop and any
cupboard/cooker hood should be as
shown below.
Minimum
42 cm
The appliance should not be installed
directly above a dishwasher, fridge, freezer,
washing machine or clothes dryer.

2.2 Installation of the appliances

The appliances are supplied with
installation kits and can be installed in a
worktop with the appropriate dimensions.
The dimensions for hob and oven
installation are given below.
Installation dimensions for hotplate hob
A1 (mm)
580
B1 (mm)
510
C1 (mm)
D1 (mm)
560
Installation dimensions for vitroceramic
hob
A1 (mm)
590
B1 (mm)
520
C1 (mm)
D1 (mm)
560
Installation dimensions for oven
A2 (mm)
557
B2 (mm)
550
C2 (mm)
595
D2 (mm)
575
I2(mm)
25
EN - 9
HOB
E1 (mm)
min. F1 (mm)
40
min. G1 (mm)
E1 (mm)
min. F1 (mm)
41
min. G1 (mm)
E2 (mm)
min. F2 (mm)
min. G2 /J2 (mm)
H2 (mm)
Minimum
42 cm
490
50
50
490
50
50
574
560-580
555/5
600

Publicité