The motor and other electrical parts are within the turbine casing. Only installers with appropriate
rights and expertise (authorised Allaway maintenance companies) are allowed to open the turbine
casing.
The central unit is equipped with protections that are designed to stop the machine in case
of any disturbances. The machine may be damaged, if it is used without investigating why
the protections were tripped and removing the cause. The protections should not be used as
indicators of e.g. the dust bag being filled or the machine requiring maintenance, or as enabling
use and installation contrary to the instructions.
Bypass valve
The Duo central unit has a mechanical bypass valve, which makes a hissing sound when e.g.
the nozzle gets stuck to the floor. The valve will close and the hissing sound stop when the
situation is back to normal.
Overload protector
The overload protector in the Duo unit stops the machine in the event of electrical overload or
damage. The overload protector cannot be reversed, and it should be replaced in an authorised
Allaway maintenance company. When changing the overload protector, the reason for its tripping,
as well as any other faults, must be established and resolved.
Overheating protector
The overheating protector stops the device if the temperature of the motor or turbine is too high.
Wait for the motor to cool down and the overheat protector to be reversed. This should take
approximately 60-90 minutes. Investigate the cause of the malfunction. The causes may include
a full dust bag or a blockage in the exhaust air filter, suction hose, or piping. Correct the cause.
The overheat protector will reset automatically.
9
Leakage test for the piping
Close all wall inlets. Start the central unit on the low-voltage terminal with a wire. Close the
bypass valve with a strip of cardboard. If air comes out from the exhaust port after approximately
10 seconds of use, there is a leak in the piping. Locate and repair the leakage. Do not use the
machine for more than 20 seconds with all wall inlets closed, because when the turbine receives
no air, it will overheat and may be damaged.
for an electrical device
Allaway Oy, Kangasvuorentie 32, 40340 Jyväskylä, Finland, declares that
The central vacuum cleaners TD-1450-AC-..-.., TD-1650-AC-..-..
have been manufactured in accordance with the relevant harmonised standards and fulfills
the essential requirements of the Low Voltage Directive (2006/95/EC), the Electromagnetic
Compatibility Directive (2004/108/EC) and the Restriction of the use of certain Hazardous
Substances in electrical and electronic equipment RoHS 2 Directive (2011/65/EC).
18

SAFETY GUARDS

LEAKAGE TEST

DECLARATION OF EC CONFORMITY