Note: During normal operation, the inlet valve shall be set in the status
of "open".
2.
Insert the supply plug into the socket, the two indicator lights will be on at
the same time..
3.
This machine can automatically control the temperature. When the water
temperature inside the machine has reached the set temperature (It is set
to 75℃), it will be turned off automatically, and step into the status of
thermal insulation; when the water temperature is decreased to a certain
point, it will be turned on automatically to restore the heating, and the use
of hot water will not be interrupted. When the heater is switched off auto-
matically, the heating indicator will turn off.
4.1 Operating Of The Unit
"Thermostat" knob, rotate the thermostat knob to set the temperature. Maximum set temperature
①
is 75 ℃. Then the heating indicator light on.
②
"Power" indicator light, plug in the power, the power indicator light will light ON reservation.
"Heating indicator"light. When the water is heated to the set temperature, this indicator light is OFF
③
and the water heater will be in a state of insulation.
1.
The supply socket must be earthed reliably. The rated current of the socket
shall not be lower than 10A. The socket and plug shall be kept dry to
prevent electric leakage. Inspect frequently whether the plugs are well
plugged in the socket. Inspect method is as follows: insert the power
supply plug into the socket,after using for half an hour, shut down the unit
and pull the plug out, and inspect the plug in case it scalds your hand. If
tempeature is over 50 ℃, please plug in another socket. to avoid the plug
being damaged, fire or other personnel accidents result from badcontact.
2.
For the places or the wall where the water may splash, the installation
height of the socket shall not be lower than 1.8m.
3
HEATING
POWER
HIGH
2
6
1
(Fig.7)