Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner,
or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper
Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and
Hose/Regulator to Grill.
LIGHTING THE SIDE BURNER:
1. Open lid before lighting side burner.
2. Make sure control knob is in the "OFF" position.
3. Push and hold down side burner control knob and SLOWLY
(2 to 3 seconds ) turn to " IGNITE ". You should hear the
igniter click.
Note: Step 3 may need to be repeated 2-3 times to light
side burner.
4. If ignition does NOT occur in 5 seconds, turn control knob
to OFF, wait 5 minutes to allow gas to dissipate and repeat
lighting procedure.
5. To turn off, turn control knob clockwise until it locks in OFF position.
MATCH LIGHTING THE SIDE BURNER:
1. Open the lid to the side burner before lighting.
2. Turn the burner control knob to "OFF".
3. Strike and carefully place a match approximately 1/2" (1 to 2 cm) from the burner.
4. Turn the side burner control knob to the "HIGH" position. The burner should light within 5 seconds.
5. If the burner does not light, turn the control knob to "OFF" and wait 5 minutes for gas to dissipate and
repeat lighting procedure.
6. If the burner does not light within the first few attempts of match lighting, there is a problem with the
gas supply. Turn off the gas at the burner and cylinder. DO NOT attempt to operate the grill until the
problem is found and corrected. See "Trouble Shooting" section of this manual.
Note:
Observe flame height when lit: Flame
should be a Blue/Yellow color between
1"– 2" when burner is on " HIGH".
TURNING OFF THE GRILL:
1. Turn off the cylinder valve.
2. Turn all burner control knobs to the "OFF" position.
Note:
Turn off LP cylinder first to prevent gas from
being left in the system under pressure.
CAUTION!
•
The cylinder valve should always be in the off,
or closed, position when the grill is not in use.
To turn off the cylinder valve,
turn knob clockwise until it stops.
11