3. Opening delay and opening window
3.1 Enable opening delay and opening window
Opening delay 1-99 minutes:
The waiting time before you can open the lock.
Opening window 1-9 minutes:
In this window you have to enter the code again to open the safe.
You can only program an opening delay and window by using the master code.
Make sure that the safe door is open when you start programming an opening delay and window (ON – master
code – ENTER)
Step
1.
Press ON
2.
Press Enter
3.
Press 6
4.
Press Enter
5.
Enter the master code, e.g. 567891
6.
Press Enter
7.
Enter the opening delay using two digits, e.g. 5 minutes
8.
Enter the opening window using single digit, e.g. 1 minute
9.
Press Enter
The opening delay and the opening window are now set.
16
24
Press code - start opening delay
Waiting time opening delay
Opening window - re-enter your code
Action
Key
Signal
ON
Enter
6
Enter
567891
Enter
05
1
Enter