Télécharger Imprimer la page

edc LIMPET Guide D'installation Et D'utilisation page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Specifications
12
3
11
10
9
8
2
7
6
5
4
1
3
2
1
0
0
0
1
1
2
0
Trouble Shooting
Pump does not run:
Check fuse and electrical supply
connections.
Check that water is reaching the pump
sensor.
Pump is pumping air:
Check that the collection tray is level.
Check that the sensor is clean and
undamaged.
Check that the outlet tube is not
syphoning.
Power supply:
Power consumption:
Alarm relay:
Capacity:
Maximum head:
Ambient temp:
Water temp:
Material:
Discharge tube:
Dimensions:
IP:
3
4
5
6
7
8
10
20
120/240Vac, 50/60Hz Auto sensing
16W max., 0.25W when idle
5A, 30Vdc, 250Vac Break on fault
12 litres/hour max. (3.17 US gal/h)
Vertical >20m (65 ft), Horizontal >100 m
(328 ft) Suction 1 m max. (3.28 ft)
0 - 40°C
25°C max.
Flame retardant ABS UL94 5VA
6mm (1/4") ID
286 x 61 x 53mm (11.3" x 2.4" x 2")
44
Capacity
9
10 11
12 13 14
30
40
Vertical lift
Pump is noisy:
Check that the mains cable and outlet tube
are not vibrating against the sides of the
equipment.
Pump continues to run with no water:
The sensor may be contaminated by dirt,
mould or certain cleaning chemicals. Gently
wipe the sensor with a damp cloth. If the
problem persists, repeat with methylated
spirit and then rinse with water.
50m Horiz
100m Horiz
15
16 17 18 19 20
50
60
GB
0m Horiz
(m)
(ft)
5

Publicité

loading

Produits Connexes pour edc LIMPET