Settings
All Setting options for the hydraulic unit and the remote
control are accessed via this sub-menu.
A four digit code must be entered to access the settings sub-
menu. This code is 0012.
The code is stated one digit at a time, from left to the right. The
arrow keys scroll from 0-9 and the OK button confirms.
The SETTINGS" menu consists of seven sub-menus, which
in turn consist of a number of part menus:
1. Select language
2. Adjust the hydraulic valve for the blade
3. Adjust the hydraulic valve for the feed
4. Sensor on/off calibrate
5. Hydraulic unit settings
6. Basic setting
7. Out settings
1. Select language
Using this sub-menu you can set the language you wish to
use on the display.
The sub-menu always has the heading in English. The
selected language is stated under heading.
To select the language:
•
Scroll using the arrow keys until the required language is
shown.
•
Press OK to confirm the selection.
•
Press the down arrow to continue to the next submenu.
2. Adjust the hydraulic valve for the blade
This sub-menu contains setting options for the rotation of the
blade and consists of three part menus:
2.1 Change the start point for the blade
2.2 Change the end point for the blade
2.3 Change the ramp time for the blade
2.1 Change the start point for the blade
The start point value should be adjusted so that the blade
rotation is as low as possible when the blade rotation knob
(pos. 2) is turned from its left-hand position.
A too low value results in the need to turn the knob before the
blade starts to rotate.
A too high value results in the blade rotating too quickly when
the knob is turned.
14 –
English
SETTINGS AND ADJUSTMENTS
2.2 Change the end point for the blade
The end point value should be adjusted so that the blade
rotation is as high as possible when the blade rotation knob is
turned to the right.
A too low value results in full power from the hydraulic unit
never being reached.
State the end point value:
•
Press OK when the part menu is shown.
The display shows: CHANGE END POINT and a
percentage value.
Scroll using the arrow keys to state the required end point.
Hold the arrow key held down to increase the scrolling
speed. The scale is graduated from 1-100 %.
•
Press OK to confirm the selection.
•
Press the down arrow to continue to the next part menu.
2.3 Change the ramp time for the blade
The ramp time value states how fast the blade's speed of
rotation shall change when the blade rotation knob is turned.
A too low value means the blade motor's hydraulic system will
start to self-oscillation.
State the ramp time value:
•
Press OK when the part menu is shown.
The display shows: CHANGE RAMP TIME and the time in
seconds.
•
Scroll using the arrow keys to state the required ramp
time. Hold the arrow key held down to increase the
scrolling speed. The scale is graduated from 0.0 to 9.9
seconds.
•
Press OK to confirm the selection.
•
Press the down arrow to continue to Back to the menu".
3. Adjust the hydraulic valve for the feed
This sub-menu contains setting options for blade feed, both
horizontally and depth.
The sub-menu consists of five part menus:
3.1 Change the start point for the trolley motion
3.2 Change the end point for the trolley motion
3.3 Change the start point for depth feeding
3.4 Change the end point for depth feeding
3.5 Change the ramp time for the feed