When the machine has been transported to a suitable site, it
should be connected:
1 Check the hydraulic fluid level in the power unit. This is
checked with the level indicator.
Min. level = red line
Max. level = black line
Do not exceed the max. level when filling the tank with
hydraulic fluid. The hydraulic fluid expands when it gets
hot and can overflow if the level is too high. Tank volume
16 l (4.2 US gallons).
2 Connect the incoming power cable (400 V, 63 A or 400 V,
32 A European connector). The cable must be threephase
and earthed. When the machine is equipped with a single
phase socket there must also be a neutral otherwise the
single phase socket on the distribution box will not work.
3 The power unit must be connected through a 63 A fuse in
order to use maximum power. If connected through a 32
A fuse, the saw must be operated at low pressure, and
with that cut less effectively to avoid overloading the fuse.
10 –
English

ASSEMBLY

4 Connect the incoming water hose to the water coupling on
the bottom of the motor front on the hydraulic unit.
5 Connect the remote control using the supplied Canbus
cable. Tighten the cable connector screws by hand.
When the machine is equipped with a radio, a radio
antenna can be connected instead of a Canbus cable.
This is screwed into the same socket as where the
Canbus cable should have been fitted.
6 Check that the emergency stop button on the power unit
and the stop button on the remote control are not pressed
by turning the them clockwise.
7 The display now shows SELECT FUSE 32A". If the
available fuse is 32 A, confirm this by pressing the
membrane key marked OK". If there is a 63 A fuse
available, press the membrane key marked up arrow". The
display now indicates SELECT FUSE 63A". Confirm this
by pressing the membrane key marked OK". ( Menu
functions / 2. Select fuse".)