drastically reducing the amount of water used for effi-
cient cleaning.
EFFECTIVENESS: reduction of backwash time and
improved filter-cleaning efficiency.
SAVINGS: a minimum of 25% water savings over
standard pumps.

2. HANDLING

It is supplied in suitable packaging to prevent it dete-
riorating during transport. Before unpacking the
product, check that the packaging has not suffered
damage or is misshapen.
Handle the product carefully, with the right tools.

3. INSTALLATION

This equipment is designed for use indoors.
3.1. Pump installation.
WARNING: Follow the installation manual in-
structions for the standard pump.

3.2. Electrical connection

The electrical installation must have a multiple
separation system with a 3 mm contact opening.
The system's protection will be based on a dif-
ferential switch (∆fn = 30 mA).
The equipment is supplied with a power cable with
plug.
Do not handle the equipment.
3.3 ControlSystem
ControlSystem installation
ControlSystem
ControlSystem
Fit the ControlSystem to the multiport filter valve con-
trol. (See figure 1)
• Select a location as near as possible to the turning
centre.
• Clean the surface with alcohol.
• Lift
the
protective
ControlSystem into the chosen place.
• Watch the "ControlSystem" position. Screw area
should be closer to the rotation axis.
• Secure the assembly by tightening the tape under-
neath the control. Check that it is fixed properly.

4. START-UP

4.1 Starting up the equipment.
Follow the installation manual instructions for the
pump to start it up properly.

4.2. Initial configuration

The first time you start it up you need to link SilenPlus
with ControlSystem (See figure 2)
WARNING It is very important to follow the or-
der of the operations described here:
4.2.1 Starting up the Evopool
• Connect the SilenPlus pump to the power supply.
The system will start up and a set of lights indicates
that it has been activated.
stickers
and
plug
the
If a ControlSystem has not already been linked to it,
the pump will not start up.
SilenPlus is on standby waiting for the link to be estab-
lished. The 3 LEDs flash together.
4.2.2 Activating the ControlSystem
To prevent the battery running out before the equip-
ment is started up, the ControlSystem has an internal
ON/OFF switch that must be activated (See figure 2)
CAUTION. Do not approach magnetic elements
to ControlSystem during this operation.
Ensure that no magnetic fields can affect the
proper operation of the system.
WITH THE PUMP CONNECTED TO THE ELECTRICAL
CURRENT (see 4.2.1):
• Make sure the valve is in the intermediate position
between 1 and 4
• Lift the cover, loosening the screw.
• Activate the ControlSystem by moving the mini-
switch to the "ON" position.
When the battery is connected, ControlSystem trans-
mits a unique code for an interference-free link.
Flashing LEDs indicate that proper communication
has been achieved. The green LED will light.
Replace the cover and fix it with the screw.
Torque: 0.2 Nm.
4.2.3 Calibrating the ControlSystem
The 6 valve positions must be indicated to the system.
For this purpose, use the following calibration process
(See Figure 3):
• Move the valve control to position 4. Wait for the
green LED is illuminated.
• Move the valve control to position 6. Wait for the
green LED is illuminated.
• Move the valve control to position 2. Wait for the
green LED is illuminated.
• Move the valve control to position 5. Wait for the
green LED is illuminated.
• Move the valve control to position 3. Wait for the
green LED is illuminated.
• Move the valve control to position 1.
The pump will start up in Remote FiltrationPlus mode.
The corresponding LED will come on.
4.3 Multiple system
In an installation with several pieces of equipment,
SilenPlus must be started up and the ControlSystem
activated in order.
Each piece of equipment is linked using a unique code
to prevent interference between them.
A SilenPlus in standby mode will be linked to the first
ControlSystem activated.
WARNING: activate the ControlSystem of the
valve for the equipment on standby.
4.4 In the absence of ControlSystem