• Only use the device for its intended purpose. All other uses may lead to short circuits, burns,
electroshocks, lamp explosions, crashes, etc. Using the device in an unauthorised way will
void the warranty.
4. Installation
a) Installing or Replacing a Lamp
CAUTION : Only install a lamp when the device is unplugged from the mains and replace it if it
has been damaged in any way.
• The lamp reach extreme temperatures during operation, so you should let them cool down
before replacing them
• Do not touch the lamp with your bare hands. Use a cloth to handle the lamp during insertion
and removal.
• Do not install a lamp with a higher wattage as it generates higher temperatures than those for
which the device is designed.
• Use one E14 socket lamp (12V/12W). Reference : LAMPRL.
1. Unscrew the cover on the side of the housing.
2. Remove the cover.
3. Remove the old lamp and insert the new one.
4. Replace the cover.
5. Tighten the screws.
Note : Do not operate the device with an open cover!!
b) Mounting the Device
Remark : Please consider the contents of EN 60598-2-17 and your own national norms during
installation. A qualified technician should carry out the installation!
• The supporting structure for the device must be able to carry 10 times the required weight for
one hour without deformation of that structure.
• The installation must always be secured by a secondary safety attachment e.g. a safety
cable (VDLSC7 or VDLSC8).
• Do not stand directly below the device when mounting, removing or repairing it. Have a
qualified technician check the installation once a year and once before you bring the device
into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience : calculating work load limits, determining
the installation material to be used... Have the material and the device itself checked
regularly. Do not attempt to install the device yourself if you lack these qualifications as
improper installation may result in injuries.
• Make sure there is no flammable material within a 50cm radius of the device.
• A qualified electrician should carry out the electric connection.
• Connect the device to the mains with the adapter.
• The installation has to be approved by an expert before the device is taken into service.
VDL15RLxA
Procedure
Procedure
2