JB Systems DYNAMO Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
ENGLISH
The DMX-protocol is a widely used high speed
signal to control intelligent light equipment.
You need to "daisy chain" your DMX controller
and all the connected light effects with a good
quality XLR M/F balanced cable. To prevent
strange behavior of the light effects, due to
interferences, you must use a 90Ω to 120Ω
terminator at the end of the chain. Never use
Y-splitter cables, this simply won't work!
Each light effect in the chain needs to have its
proper starting address so it knows which
commands from the controller it has to
decode.
 How to set the DIP-switches to obtain the right starting address:
On the back of the Dynamo you will see that each of the first 9 DIP-switches corresponds to certain
value:
Dip
#1
#2
#3
#4
#5
Value
1
2
4
8
16
You can combine the values of these switches to become any starting address between 1 and 512:
 switch 1=ON
Begin address = 01
 switch 1+3=ON
Begin address = 05
 switch 1+4=ON
Begin address = 09
 switch 1+3+4=ON
Begin address = 13
 switch2+3+4+5+6=ON
Begin address = 62
 DMX-CONFIGURATION OF DYNAMO, DYNAMO 250 & DYNAMO 250 BARREL:
JB SYSTEMS
®
OPERATION MANUAL
#6
#7
#8
#9
32
64
128
256
values: 1
values: 1+4 = 5
values: 1+8 = 9
values: 1+4+8 = 13
values: 2+4+8+16+32 = 62
5/41
DYNAMO & DYNAMO 250 (BARREL)
ENGLISH
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 230V, 50Hz
Fuse:
250V 3.15A fast blow (20mm glass)
SoundControl:
Internal microphone
DMX connections:
3pin XLR male / female
Lamp:
DYNAMO: EFP 100W / 12V
DYNAMO 250 & DYNAMO 250 BARREL: ELC 250W/24V
Size:
38.5 x 17 x 12cm
Weight:
DYNAMO: 3.8kg
DYNAMO 250: 4.4 kg
DYNAMO 250 BARREL: 4.4 kg
Dynamo:
Dynamo 250:
Dynamo 250 Barrel:
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
®
OPERATION MANUAL
6/41
DYNAMO & DYNAMO 250 (BARREL)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dynamo 250Dynamo 250 barrel

Table des Matières