PA220
32
5 Limit programming
Limit programming does not relate to module configuration and can
be performed at all times.
How to proceed:
1. Press
, [Pro] appears in the display to signal access to program-
ming mode. LED PROG is flashing.
2. Select first limit using key
Limit 1 LED SET 1 lights up.
Press keys
and
3. Press
to access limit 2.
Limit 2 LED SET 2 lights up.
Press keys
and
4. Press
to save both limits and to exit programming mode.
6 Programming lock by authorization code
Parameterization can be locked by code against unauthorized altera-
tion:
- either totally
With overall programming lock the individual configuration modules
will be provided but do not enable parameter changes, which is
indicated by [DAtA] appearing in the display instead of [Pro] when
accessing programming mode.
- or in part
by selecting the configuration modules to be protected. Here as well,
the modules remain visible but do not allow for parameter changes.
Enter or change code
1. Press key
and hold for 3 seconds. [CodE] appears in the display
and LED PROG lights up.
2. Enter code using key
„0000".
3. Change code
No
Yes
Enter new code within the range of 0000 and 9999
4. Total lock
No (partial lock)
Yes
www.baumer.com
.
to change limit 1.
to change limit 2.
and
Default code at delivery is