Display
4 digits
Sticker to indicate measuring unit

2.3 Limit outputs

The device provides 2 relay limit outputs. Output trigger either at ≥
displayed value or ≤ limit is defined by HIGH or LOW configuration.
The outputs can be configured as time delay or hysteresis.
Limit outputs as time delay
Time delay parameterization is within the range from 00 to 99 s and
will be effective both at limit output power on and off.
Limit 1
Limit 2
Delay
Delay
Relay 1 =
HIGH
Relay 2 =
Delay
Delay
LOW
Asymmetrical hysteresis
Hysteresis is configured in display units from 0 to 9999 and only ef-
fective at limit output power off.
Limit 1
Hysteresis
Limit 2
Hysteresis
Relay 1 =
HIGH
Relay 2 =
LOW