TROUBLESHOOTING

SYMPTOM
POSSIBLE CAUSE
No display on controller
No power
Same as above
Controller not
connected
Same as above
Blown fuse or other
internal circuit failure.
The nozzle won't stay when
The nozzle removal lever is
inserted into the heater head
stuck in the "release" position
The "removal complete" icon
Vacuum tube pushed too high
appears immediately upon
by a tall component.
starting a removal.
The "removal complete" icon
Same as above
appears after 5 seconds, the
vacuum cup is still holding the
component, but the component
is still attached to the board.
The "removal complete" icon
No vacuum cup, or vacuum
appears after 5 seconds, and
cup is too small
the vacuum tube has pulled
away from the component
without removing it.
The "removal complete" icon Dirty, torn, cracked or
appears before the
hardened vacuum cup
component is removed, and
the vacuum cup has pulled
off the component.
Same as above
Vacuum cup is crooked on
the vacuum tube and doesn't
rest flush on the component.
Same as above
Low vacuum due to a
clogged or leaking tube,
filter, or pump
Same as above, except it
Vacuum cup is too cold and
mainly occurs when the
therefore too stiff to hold
machine is just started or
with a new vacuum cup
The component lifts from the
Component leads are caught
board, but the hot air does
on one of the nozzle flutes
not stop.
Same as above
Same as above
Same as above
The vacuum cup is pushed
too far onto the tube, so it
can't rise enough
Same as above, except only
The spring is too weak
with very large components
to lift the component
14
Copyright © 1999, Metcal, Inc. All Rights Reserved 7036-0541 Rev. A
SOLUTION
Be sure power cord is plugged into the power
supply and a grounded outlet and the power
switch is ON.
Be sure the controller cable is plugged into the
controller and the power supply.
Call Metcal RMA Department.
Rotate the lever away from the stopping point and
try inserting the nozzle again.
Remove and re-attach the vacuum cup per the
directions in this user guide. Then use the Z-axis
knob to lift the nozzle farther from the component
during removal so the vacuum tube is not pushed
up as far.
Same as above
Attach a vacuum cup per the directions in this
guide. See p. 11.
Remove the old vacuum cup and install a new
one per the directions in this user guide.
(See also "Maintenance - Vacuum Cup")
Remove and re-attach the vacuum cup per the
directions in this user guide.
Replace the vacuum cup and clean the vacuum
tube per the directions in "Vacuum Tube
Maintenance". If the problem persists,
contact Metcal Customer Care.
Hold the top of the vacuum tube for at least five
seconds until the vacuum cup can hold for itself.
Be sure you are using the correct nozzle for that
component. Nozzles are designed to allow space
for the component leads.
(See the Nozzle Selection Chart)
Be sure the part is centered under the nozzle
when the cycle begins.
Remove and re-attach the vacuum cup per the
directions in this user guide.
Contact Metcal Technical Services for
instructions on how to increase the spring
tension.

ERROR CODES

The QX2 is programmed to identify certain problems in the proper function of the
system. If one of these problems occurs, the system will shut down and one of the
following error codes will appear on the controller display. The system must be
turned off to reset the error message.
"Int Temp Error"
The internal temperature of the power supply is too high and
may damage the electronic circuitry. If this error occurs
repeatedly, the QX2 should be moved to a cooler location.
"Overtemp Error"
The temperature of the heater is too high. Contact Metcal
Technical Services if this error occurs repeatedly.
"Heater Error"
The controller has not detected a temperature from the heater,
indicating a broken heater or thermocouple.
"Control Timeout"
The power supply and controller have been out of
communication for too long. This error will occur if you
unplug the controller cable while the system is on.
"Comm Error"
The power supply or controller got a signal that it did not understand.
If it happens repeatedly, contact Metcal Technical Services.