Remedy Of Faults; Wear Parts - Oase FiltoClear 3000 Notice D'emploi

Masquer les pouces Voir aussi pour FiltoClear 3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Commissioning/start-up
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
How to proceed:
• Fit the connections ( Assembly).
• Check the firm seating of hoses, cover cap for soiled water drain, clamping ring with safety latch.
• Turn the function switch (J 5) to water filtering (40), if it is not already in this position.
• Switch on the pond pump.
• Only switch on the UVC unit when water is flowing through it. You may have to wait for 24 hours.
Connect power plug to the socket. The UVC unit switches on immediately, the blue LED (J 33) is lit.
Operation
The unit is no longer biologically active at water temperatures below 50 °F (10 °C). Take the unit out of operation at
water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are to be expected.
Normal operating condition: The UVC unit is switched on. The UV-C lamp must be replaced after approx. 8000 opera-
ting hours.

Remedy of faults

Malfunction
No water flow through the re-
turn socket.
UVC lamp display is not lit
Filtering performance not satis-
factory

Wear parts

The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Cause
− Filter pump not switched on.
− Supply lines blocked.
− Function switch not turned to "Filter water"
− Connection defective or has not been made.
− Temperature monitor has switched off the UVC
lamp
− UVC lamp defective
− Quartz glass tube not fitted
− Function switch not turned to "Filter water"
− Unit has not been in operation long enough
− Water extremely soiled
− Excessive fish and animal population
− Foam filters clogged
− Quartz glass tube soiled
− UVC lamp is in operation for more than 8000
hours
Remedy
− Switch on the filter pump
− Check supply lines
− Turn function switch to „Filter water"
− Check connection (power plug, power fuse)
− Allow the UVC lamp to cool down
− Replace UVC lamp
− Fit quartz glass tube
− Turn function switch to „Filter water"
− Wait a few days/weeks
− Adhere to the reference value
− Clean foam filters
− Cleaning the quartz glass tube
− Replace UVC lamp