MAINTENANCE
(a1)
Every Week
Press each switch or push button individually in turn, check that the
MSR7R outputs do not close. Press both switchs simultaneously
(within 0.5secs), the MSR7R outputs should close, release one
switch, Check that the MSR7R outputs open immediatly and that
they cannot be closed again until both switchs have been released
and then pressed simultaneously. During these tests, check that the
LED's are operating correctly.
At least every 6 months
Isolate all power! Check for correct terminal connections and check
wiring for signs of damage.
REPAIR
(b1)
If there is any malfunction or damage, no attempts should be made
to repair it. The control unit should be replaced before machine
operation is allowed.
DO NOT DISMANTLE THE UNIT.
TROUBLESHOOTING
(c1)
Symptom
Output contacts fail to close
Output contacts fail to close
Output contacts fail to close
Output contacts fail to close
Symptom
Ausgang schließt nicht
Ausgang schließt nicht
Ausgang schließt nicht
Ausgang schließt nicht
Symptôme
le contact de sortie ne se ferme pas
le contact de sortie ne se ferme pas
le contact de sortie ne se ferme pas
le contact de sortie ne se ferme pas
Jede Woche
Jeden Taster einzeln drücken und prüfen, daß kein Ausgangssig nal
ausgelöst wird. Dan beide Taster gleichzeitig drücken (innerhalb
0,5s), und das Gerät muß schalten. einen Taster loslassen und
prüfen, ob das Gerät sofort abschaltet und nicht wieder einschalten
kann, bevor beide Taster losgelassen und dann gleichzeitig gedrückt
werden. Bei diesen Test prüfen, ob die LED's korrekt arbeiten.
Wenigstens alle 6 Monate
Spannung abschalten. Anschlüsse und Verdrahtung auf Schäden
überprüfen.
Falls Fehlfunktionen oder Schäden auftreten, keine Versuche zur
Reparatur unternehmen. Der Schalter muß ersetzt werden, bevor die
Maschine wieder gestartet wird.
GERÄT DARF NIEMALS GEÖFFNEN WERDEN!
LED Status
Power K1
K2
Cause
OFF
OFF OFF
Fault on power supply to Minotaur.
ON
ON
OFF
Fault on one switch or input circuit.
ON
OFF
ON
Fault on one switch or input circuit.
ON
OFF
OFF
Fault on input circuit.
LED Status
Power K1
K2
Ursache
Aus
Aus Aus
Fehler an Spannungsversorgung
An
An Aus
Fehler am Eingangskreis
An
Aus An
Fehler am Eingangskreis
An
Aus Aus
Fehler am Eingangskreis
Etat de diodes
alim K1
K2
Cause
OFF
OFF
OFF
panne d'alimentation du Minotaur
ON
ON
OFF
panne d'un interrupteur ou du circuit d'entrée
ON
OFF
ON
panne d'un interrupteur ou du circuit d'entrée
ON
OFF
OFF
panne sur le circuit d'entrée
WARTUNG
REPARATUR
FEHLERSUCHE
Chaque semaine
Presser chaque interrupteur et chaque bouton poussoir tour en
vérifiant que les sorties du MSR7R ne se ferment pas. Enfoncer
simultanément les deux interrupteurs (en moins de 0.5 secs), les
sorties du MSR7R doivent se fermer, relâcher un des interrupteurs
vérifier que les sorties du MSR 7R s'ouvrent instantanément et
qu'elles ne peuvent pas être de nouveau fermés sans que les deux
interrupteurs aient été relâchés et réenclenchés simultanément.
Pendant ces testes vérifier que les diodes LED fonctionnent
correctement.
Au moins une fois tous les 6 mois
Couper toute alimentation! Vérifier l'état des connexions sur les
broches du MSR7R et l'état du câblage.
En cas de dysfonctionnement ou de dégradation, ne pas attendre
pour réparer. L'interrupteur doit être remplacé immédiatement avant
le démarrage de la machine.
DANS TOUS LES CAS, NE DISLOQUEZ PAS L'APPAREIL.
LOCALISATION DE PANNE
Drg No: 23877 Issue No: 5
MAINTENANCE
REPARATION
Change No: 14213