Operating instrutions
10.1 Assembling the power plug
Connect the power cable to the pump as shown. Caution: Line voltage! Observe the required
protective measures, national body regulations and local provisions at all times. The cable cross-
section may be no smaller than 0.75 mm2. Use ferrules if using fine-wire cables.
11 Filling and Venting the System
36
WITA Delta Maxi 80-XX
1
3
2
Fill and vent the system correctly. To vent the pump, loosen
the indicated screw by turning it anti-clockwise. Caution! Hot
water may escape here, depending on the system's operating
state. Afterwards, re-tighten the screw and start the venting
programme (see section 7.5 on page 30).
After this process, you can start the pump in
the desired control mode.
Incomplete venting can lead to noises
in the pump and system.
Warning! Risk of burns! The entire
pump can be very hot, depending on
the operating state of the system.
2
Click
4
Click
Note