Cooper Lighting Metalux VT3 Instructions D'installation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions – VT3 LED Vaportight Luminaire Installation
Emergency Battery Backup
Only the 4ft 4000 and 6000 lumen configurations have integral EM battery packs. All others are remote mount only. The
remote battery pack is housed separately in a 2ft VT housing and connected to the primary unit with a 3ft length of liquid-
tight conduit and straight fittings with the units pre-wired. Only the EM unit requires input supply wiring. Once in operation
and a/c power applied, connect the 2 red "converter connector" wires with supplied wire nut. The test button & indicator
light is located in the EM housing for remote units and on the gear tray for integral units.
4
COOPER LIGHTING SOLUTIONS
IB519084EN
Installation instructions

Publicité

Table des Matières
loading

Table des Matières