- EN -
Technical data
Nominal input voltage (primary voltage)
Nominal input current (primary current intake)
Nominal input frequency
Nominal output voltage (secondary voltage)
Nominal output current (maximum secondary current)
(per output)
1)
Rated capacity
per output
1)
Rated capacity
total
Efficiency
Residual ripple
Starting current
Reset duration after triggering of the overload protection
Protection class
Isolation between the primary/secondary side
Maximum submersion depth
Length of power cable
Permissible water temperature
(operation in water, product active)
Permissible ambient temperature
(operation outside the water, product active)
Storage temperature (product inactive = disconnected from the power
supply)
Standard
Dimensions (length × width × height)
Weight
Article number
1)
The values were determined after an operating time of 15 minutes and at an ambient temperature of 68 °F (+ 20 °C)
OASE connection cable
The maximum admissible current of the connection cable depends on the length of the cable.
Type
Connection cable
24 V DC/01
Symbols on the unit
6
1)
1)
1)
1)
Length (Order No.)
Conductor cross section
3.28 ft (1 m) (12762)
9.84 ft (3 m) (12552)
24.60 ft (7.5 m) (12375)
49.21 ft (15 m) (11740)
Read the instructions for use.
Protect from direct sun radiation.
Dust-tight. Watertight to a depth of 13.1 ft (4 m).
10.24 inch x 6.38 inch x 3.03 inch (260 mm × 162 mm × 77 mm)
0.078 × 0.098 inch²
Output voltage
2 × 2.5 mm²
Max. cable length
100-240V AC 10 %
max. 4.1 A
50/60 Hz
25 V DC 3 %
max. 3.2 A
max. 80 W (Class 2)
max. 240 W
92 %
1 % (U
250 mV)
pp
max. 15 A for 4 ms
5 minutes
IP 68
galvanic
13.1 ft (4 m)
20 ft (6 m)
39 °F ...95 °F
+ 4 °C ...+ 35 °C
14 °F ...104 °F
- 10 °C ...+ 40 °C
- 4 °F ...158 °F
- 20 °C ...+ 70 °C
UL 1310 / CSA C22.2 No. 223
10.6 lbs. (4.8 kg)
40289
Maximum admissible current
10 A
49.21 ft
15 m
5 A
7.5 A
65.61 ft
98.42 ft
20 m
30 m