RAIS 500 1G Manuel D'utilisation page 49

Table des Matières

Publicité

English
Mounting distance for panelled wall - non-combustible material
Recommended min. convection area
above the stove:

800 cm² (may be distributed)

A
A
Recommended min. convection area below

the stove: 500 cm² (may be distributed)




Distance to combustible material

min. 200 mm (e.g. side wall)




It is recommended to knock out the 3 areas -

prepared for heat transfer
Distance to combustible material
min. 150 mm (e.g. door frame)



To guide the hot air out of the gratings,
we recommends to install a non-flam-

mable plate just above the holes.


A-A





RAIS - manual for RAIS 500
NB!!

Insulated shimney down to the

smoke connector (not included)



Distance to furniture
min. 900 mm





45