MixRite operates in the following conditions:
From a minimum flow rate of 20 L/H (5.3 Gal/H) and up to 2,500
L/H (660 Gal/H)
Temperature not lower than 4°C (39°F) and not higher than
40°C (104°F)
Water pressure between 0.2 Bar to 8 Bar (2.9 to 120 PSI)
The additive may be added to the water flow according to the
required dosing percentage:
0.1% to .9% in models: 569(CL/CW/PVDF)
0.3% to 2% in models:
576IN, 577IN.
0.4% to 4% in models:
578IN, 579IN.
3 % to 10% in models: 574(CL/CW), 575(CL/CW)
Fixed dosage 0.8 % in models: 571 Green, 568AG
Water pressure loss:
Pressure loss in the lower flow rates 0.1 Bar and in the higher flow
rates up to 1 Bar.
Models with 0.3%-2%: from 0.1 Bar up to 1 Bar in proportion to
the water flow
Models with 0.4%-4%: from 0.2 Bar up to 1.2 Bar in proportion to
the water flow
Models with 3%-10%: from 0.5 Bar up to 1.8 Bar in proportion to
the water flow
The MixRite inlet and outlet are ¾" BSPT male thread.
The additive tank should be placed beneath the MixRite.
Mounting the MixRite
1. Prepare the MixRite site.
2. Screw the MixRite bracket onto a wall or
any stable vertical base.
3. Press the MixRite onto the bracket.
The nipples on the MixRite must click
into the holes in the side of bracket.
I-870
Rev G - 37915
Technical Data
The MixRite intake and outlet must
reach the intake and outlet pipes.
The MixRite must be positioned above
the liquid additives container.
570(CW/CL/PVDF), 571(CW/CL/PVDF),
572(CW/CL/PVDF), 573(CW/CL/PVDF),
Page 3 of 36