5. Install the 6 mm nuts to the outside top or outside back
(alternate location on some models) of the range hood at the
proper location for the selected motor system.
Two 6 mm nuts are required for the single motor system.
Clip nuts into the small square notches located at the left
and right end of the square vent opening.
Five 6 mm nuts are required for the dual motor system.
Clip nuts into the small square notches, one located in
the front of the square vent opening and the other four
located at the left and right ends of the square vent
opening.
A
A
A. Clip nut (6 mm) locations for dual motor assembly (quantity five)
B. Clip nut (6 mm) locations for single motor assembly (quantity two)
6. Mount range hood using the Installation Instructions that
came with your range hood model.

Install Range Hood Blower Motor

1. Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
A
A. Wiring connection
A
B
Dual Blower Motor Assembly
A. Wiring connection
2. Slide the left mounting plate flange under the motor
mounting bracket.
A
B
A. Motor mounting bracket
B. Mounting plate left flange
3. Run the power supply wires and connector from the range
hood through the hole in the right end of the motor mounting
plate.
A. Motor mounting plate hole
B. Power supply wires and connector
A
A
B
5