Select the N
EWTRON
(Fig. 3-12) or by pressing the footswitch
button (Fig. 8-5).
On the LCD screen, the N
highlighted.
Select the program for which settings are to be
adjusted by pressing buttons
or
(Fig. 5-16) or by pressing the
footswitch button (Fig. 8-3).
Adjust the power level according to the T
recommendations.
If necessary, modify the program power level (1 to
10) using buttons
The power level of the program concerned is shown
as a number and a bar-graph
Modify the footswitch type if necessary by
pressing button
ON/OFF and progressive.
If necessary, select handpiece light function
ON/OFF by pressing button
Confirm the new settings by pressing button
(Fig. 3-8). The saving of the various settings is
confirmed by an audible signal and a visual signal
(flashing button).
Repeat this sequence if necessary in order to
adjust all the programs.
function by pressing button
tab must be
EWTRON
,
(Fig. 3-6) and
(Fig. 3-7).
(Fig. 5-15).
(Fig. 3-10) to toggle between
(Fig. 3-11).

7. 7 TOOLBOX

Important:
P
2 has a
IEZOTOME
various adjustments, including brightness, light
off time-out, audio volume and factory
configuration reset.
,
To access the
device, wait four seconds, switch the device ON
again, then press button
welcome screen (Fig. 6).
IPBOOK
a) Audio volume adjustment
Adjust the audio volume value
using buttons
audio volume is adjustable from 0% to 100%.
The relative value of the audio volume is
displayed (Fig. 7-25).
b) Screen brightness adjustment
Adjust the brightness value
buttons
brightness is adjustable from 30% to 100%.
The brightness level setting is displayed (Fig. 7-26).
c) Light off time-out adjustment
Adjust the time-out length value
by pressing buttons
The length of the adjustable time-out (from nine
seconds to 18 seconds) is displayed (Fig. 7-27).
function used to make
TOOLBOX
function, switch OFF the
TOOLBOX
(Fig. 6-17) on the
and
(Fig. 7-22 and 23). The
(Fig. 7-20) using
and
(Fig. 7-22 and 23). The
and
(Fig. 7-22 and 23).
(Fig. 7-19)
(Fig. 7-21)
13