4.
Commissioning
Use
The UVC clarifier can be operated with a filter (⌦F) or without (⌦E).
Setting up the UVC lamp
1. Insert the provided UVC lamp into the pond clarifier.
(see Chapter 6. Maintenance - replacing the lamp).
Attaching the UVC clarifier to a solid base (⌦A)
For a secure fitting, you can attach the UVC clarifier to a solid base (e.g. a wooden or metal plate). To do so,
proceed as follows:
1. Drill the corresponding fixing holes.
2. Screw the UVC clarifier onto the wooden or metal plate.
If you want to operate the UVC clarifier without a solid base, you must ensure that the UVC clarifier is
stable on its supports.
Attaching the UVC clarifier to an EHEIM LOOP flow-through filter (⌦B)
Attach the UVC clarifier as described in the LOOP flow-through filter operating manual.
Installing the pump connection
1. Use a saw to shorten the connecting piece to the diameter of your hose (⌦C).
2. Connect the spiral hose of the pump to the connecting piece ②.
3. Insert the sealing washer ③ into the union nut ① (⌦D).
4. Screw the connecting piece onto one of the two screw connections on the UVC clarifier housing with
the union nut.
Installing the filter connection/outlet hose
1. Use a saw to shorten the connecting piece to the diameter of your hose (⌦C).
2. Connect the spiral hose of the filter or the outlet hose to the connecting piece ②.
3. Insert the sealing washer ③ into the union nut ① (⌦D).
4. Screw the connecting piece onto one of the two screw connections on the UVC clarifier housing with
the union nut.
We recommend fastening the hoses with hose clamps