EXTENSION CORDS

Use only 3-wire extension cords that have 3-prong grounding
plugs and 3-pole receptacles that accept the tool's plug.
When using a power tool at a considerable distance from
the power source, use an extension cord heavy enough
to carry the current that the tool will draw. An undersized
extension cord will cause a drop in line voltage, resulting in
a loss of power and causing the motor to overheat. Use the
chart provided below to determine the minimum wire size
required in an extension cord. Only round jacketed cords
listed by Underwriter's Laboratories (UL) should be used.
**Ampere rating (on tool data plate)
0-2.0
2.1-3.4
Cord Length
Wire Size (A.W.G.)
25'
16
16
50'
16
16
100'
16
16
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
Always use an extension cord that is designed for outside
use. This is indicated by the letters "W-A" or "W" on the
cord's jacket.
Before using an extension cord, inspect it for loose or exposed
wires and cut or worn insulation.
Use only extension cords that are intended for outdoor use.
These extension cords are identified by a marking "Acceptable
for use with outdoor appliances; store indoors while not in
use". Use only extension cords having an electrical rating
not less than the rating of the product. Do not use damaged
extension cords. Examine extension cord before using and
replace if damaged. Do not abuse extension cords and do
not yank on any cord to disconnect. Keep cord away from
heat and sharp edges. Always disconnect the extension
cord from the receptacle before disconnecting the product
from the extension cord.
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not come in contact with
the drum or mixing materials while you are using the
mixer. Failure to do so can result in serious personal injury.

ELECTRICAL

3.5-5.0
5.1-7.0
7.1-12.0 12.1-16.0
16
16
14
16
14
14
14
12
10
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use tool with a damaged cord
since touching the damaged area could cause electrical
shock resulting in serious injury.

ELECTRICAL CONNECTION

This tool is powered by a precision built electric motor. It
should be connected to a power supply that is 120 V, AC
only (normal household current), 60 Hz. Do not operate
this tool on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If the
tool does not operate when plugged into an outlet, double
check the power supply.
14

GROUNDING INSTRUCTIONS

12
See Figure 1.
This product must be grounded. In the event of a malfunction
or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. This
tool is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
WARNING:
Improper installation of the grounding plug is able to result
in a risk of electric shock. When repair or replacement of
the cord is required, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having
an outer surface that is green with or without yellow
stripes is the grounding wire.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if
in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.