GENERAL FEATURES
Items 060010 - 060014 - 060051 - 090081 qualify the same basic component of
the aspiration unit (bare or with accessories) for polishing machine and sand-
blaster for dental technicians or goldsmiths.
The aspiration cannot be started prior to its connection to the machine it is meant
for: the complete machine must then be found compliant to 89/392/EEC
regulation and its amendments.
Warnings
1- Check power supply line: 230 V ~ ± 5% .
2- Protect the aspiration unit (all three versions) against direct and indirect contact
according to CEI 64-8 regulations for class I appliances.
3- Protect the power supply line against direct and indirect contact, against
overload and overcurrent according to CEI 64-8 regulation.
4- The control board must comply to CEI EN 17-13/1 (CEI-EN 6043-1). The motor
must be protected against overload according to CEI EN 60 204-1 regulation.
5- The appliance cannot work in contact with a flammable anaesthetic mixture or
other flammable gas with air, oxygen, or nitrous oxide or with corrosive gas.
6- Connect the aspiration and pressure outlets; protect also the outlets not in use
with a filter before starting the aspiration unit.
7- Do not operate on a functioning unit.
8- For use other than that stated address to the manufacturer.
9- The unit is guaranteed for 1 year from date of sale, provided that it has been
correctly used and it is found not tampered with.
10- The manufacturer is willing to provide general and technical information.