Charging battery pack (Jetvac accu)
The battery pack which is supplied with the Jetvac accu is not fully charged.
Charge the battery pack for at least four hours to ensure that you can use the full capacity.
The charging process begins as soon as the battery pack is attached to the charger.
The average charging time for a fully-discharged battery with 45-minute operation time is ca. 2.5 hours, with
90- minute operation time 5 hours.
[02] Lay the appliance (2) upside down and open the flap on the underside
by turning the runners by 90°. Now remove the battery pack.
[03] Attach the plug of the charger with the power socket. Now insert the battery pack (14)
into the battery charger (13) and switch on the charger (10).
Display battery charger (Jetvac accu)
Red
Battery completely discharged or no battery attached
Yellow
Battery is being normally charged
Green/yellow blinking
Battery is almost fully charged
Green
Battery is fully charged
Red blinking
Battery defective
The electronics recognise a battery short circuit. When a completely discharged battery
(voltage under 21 volt) is inserted, the battery will be charged slowly until the battery voltage
exceeds 21 volts, then a change-over to normal charge takes place.
As soon as the battery pack has been completely charged, switch off the charger and pull out
the mains plug. Now remove the battery pack.
Inserting battery pack (Jetvac accu)
[04] Insert the battery pack (14) into the appliance, until the yellow locks click into place.
Close the flap and secure it by turning the guides to the starting position.
Tip:
When using the Jetvac accu you can read the state of charge
from the display when the appliance is on.
Beginning/end of cleaning
[06] Before beginning vacuuming, flip the mains switch to Level "1".
Jetvac: Pressing the grey foot switch once will switch the machine on (1, 2) and activate vacuum
setting 1; pressing the grey foot switch again (x2) activates vacuum setting 2 (highest setting); pressing
the grey foot switch again after this (x3) switches the machine off (1, 2).
When vacuuming has been completed, the mains switch should be switched to level "0" and the mains
cable unplugged from the socket.
20
Jetvac accu: Pressing the grey foot switch once will switch the machine on (1, 2) and activate
vacuum setting 1; pressing the grey foot switch again after this switches the machine off (1, 2).
When vacuuming has been completed, the mains switch should be switched to level "0"
Replacing main filter
Caution:
Switch off the appliance and pull out the plug if you wish to replace
the motor filter!
[08] Open the flap as shown.
[10] Now take out the motor filter (anthracite) (11) and dispose of it correctly.
Insert the new motor filter (anthracite) (11) and close the flap.
Replacing HEPA filter
Caution:
Switch off the appliance and pull out the plug if you wish
to replace the HEPA filter!
The optional HEPA filter (=High Efficiency Particulate Air) can pick up dust particles of 0.3 micrometer.
[05] First open the twistlock as shown. Open the flap. Now take out the HEPA filter (yellow) (10) and
dispose of it correctly. Insert a new HEPA filter (yellow) (10) and close the flap.
Strain relief (Jetvac)
[12] The strain relief prevents the cable being pulled out of the Jetvac as the result of mechanical strain.
When the cable is replaced, the new cable must be attached as shown.
Service, maintenance and care
The Jetvac and Jetvac Accu are high-quality vacuum cleaners which have been safety tested in the plant
and by authorised inspectors. Electrical and mechanical components are subject or wear and tear and
deterioration following long periods in service.
In order to maintain the operation safety and serviceability we recommend that the appliance serviced
once a year.
Only original (replacement) parts from VERMOP may be used, otherwise a loss of safety and serviceability
may result, as well as the lapse of the guarantee.
Repairs to mechanical or electrical parts may be carried out only by our staff or experts authorised by
VERMOP and familiar with all the relevant safety stipulations.
The servicing of the appliance is a precondition for fault-free functioning and a long service life.
For questions regarding service please contact your local VERMOP office.
D
UK
F
I
ES
DK
PL
HU
NL
RU
21