The natural gas supply is easy to use and gives you more cooking control than charcoal
fuel.
These instructions will give you the minimum requirements for assembling your
Weber
®
Built-In Side Burner. Please read the instructions carefully before using
your Weber
®
Built-In Side Burner. Improper assembly can be dangerous.
Not for use by children.
If there are local codes that apply to portable gas grills, you will have to conform
to them. If there are no local codes, you must conform to the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA54.
This Weber
®
Built-In Side Burner is designed for natural (piped in city) gas only.
Do not use liquid propane (LP) bottled gas. The valves, orifices and hose are for
natural gas only.
Do not use with charcoal fuel.
Check that the area under the control panel and the bottom tray are free from
debris that might obstruct the flow of combustion or ventilation air.
STORAGE
The gas must be turned OFF at the natural gas supply when
the Weber
®
Built-In Side Burner is not in use.
Check that the areas under the control panel and the slide
out bottom tray are free from debris that might obstruct the
flow of combustion or ventilation air.
OPERATING
WARNING: Only use this barbecue outdoors in a well-
ventilated area. Do not use in a garage, building, breezeway
or any other enclosed area.
WARNING: Your Weber
®
used under an unprotected combustible roof or overhang.
WARNING: Your Weber
®
to be installed in or on recreational vehicles and/or boats.
WARNING: Do not use the barbecue within 24 (60.96cm)
inches of combustible materials, top, bottom, back or sides
of the grill.
WARNING: The entire cooking box gets hot when in use. Do
not leave unattended.
WARNING: Keep any electrical supply cord and the fuel
supply hose away from any heated surface.
WARNING: Keep the cooking area clear of flammable vapors
and liquids, such as gasoline, alcohol, etc., and combustible
materials.
GAS SUPPLY TESTING
Disconnect your Weber
®
gas barbecue when the gas supply is being tested at high
pressures. This appliance and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.5 kPa).
®
Turn OFF your Weber
gas barbecue when the gas supply is being tested at low
pressures. This appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas
supply piping system at the pressure equal to or less than 1/2 psig (3.5 kPa).
Built-In Side Burner shall not be
Built-In Side Burner is not intended
INSTALLATION
"ISLAND" STRUCTURE CONFIGURATION OPTIONS
There are many available options for locating the major components of your Island
structure.Your major components are:
1)
The Built in Grill
2)
Gas supply enclosure
3)
Optional Side burner accessory
The 3 common options (A, B, C) are illustrated in the "Island Structure Configuration
Options" table.
A
1
B
1
C
1
"ISLAND" STRUCTURE CONFIGURATION OPTIONS
1
2
3
NOTE: GAS LINE LIMITATION
The gas supply hose from grill manifold to gas supply bulkhead must not exceed 58"
(147cm). The 3/8 (9.52mm) Side Burner accessory hose (not included) must not exceed
58 (147cm).
2
®
Summit
4-burner/6-burner grill
Gas supply
Optional sideburner accessory
WWW.WEBER.COM
3
2
3
3
2
®