Operation; Monitoring & Control; Masterbus Displays - Mastervolt 77031200 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61

4 OPERATION

4.1 MONITORING & CONTROL
Control of the AC Power Analyser is entirely MasterBus
based. This means you need a display.
1
LED Indication
Mode LED (yellow)
AC ok LED (Green) continuously
AC fail LED (Red) continuously
MasterBus LED (Green)
Off
On
The AC Power Analyser only functions if it is MasterBus configured!

4.2 MASTERBUS DISPLAYS

Mastervolt offers several ways of displaying your
MasterBus data. Shown is the MasterView System
Figure 2: MasterView system panel
EN / AC Power Analyser / February 2011
6 7 8 9
2
3 4
Figure 1: AC Power Analyser
Meaning
Relay state (illuminating means the relay is activated)
No errors in AC and AC present
AC voltage, current and/ or frequency out of range.
Refer to section 6.1 MasterBus Menus for adjustable ranges
No MasterBus communication
MasterBus communication
An example of such a display is shown in section
4.2 for monitoring and controlling this switching
device. The overview shows all connections and
communication LED's of the AC Power Analyser.
1. AC input
2. Current coil connector
3. Connector for potential free
4. RJ12 connector for inverter
5. MasterBus connectors
6. Mode LED
7. AC ok LED
8. AC fail LED
9. MasterBus LED
5
Another way of displaying and configuring your
MasterBus devices is the MasterView System
software, see figure 3.
Figure 3: MasterView system software
relay contact
OPERATION
7

Publicité

Table des Matières
loading

Table des Matières