6. Using the hexagon screwdriver provided, increase the torque until
the mechanical stop is engaged and then loosen by one turn.
max.
max.
DigiTorque
MultiTorque
94
7. Establish the average value for the upper section by carrying out
5 measurements using a torque meter.
8. If the torque established differs from the display, the value must be
increased or decreased as described in point 4 (page 92).
5 x
5 x
95