EN
6. Trouble Shooting
Before using the product, please be sure that Power LED is on. If the Power LED is not on, please
check the following steps:
1. Check if the mains is normal.
2. Check if the power cord is connected firmly.
3. Check if the connected devices are connected to the unit firmly.
4. Check if the unit is turned on.
Problem
Circuit breaker is
"tripped".
The unit is turned off
automatically and the
Power LED is not lit.
7. Specifications
Model
CAPACITY
Input Voltage
Input Voltage Range
Input Frequency
Voltage Regulation
Output AVR
INDICATOR
Power LED
Boost/Buck LED
PROTECTION
Comprehensive
Protection
PHYSICAL
Dimension (DxWxH)
Net Weight (kgs)
Environment
Humidity
Noise Level
Possible Cause
The unit is overload.
The unit is over-heated. It's
internal protected function.
AVR 600
600VA / 360W
Short circuit, overload, and over-temperature protection
1.7
0-90% RH @ 0-40° C (non-condensing)
Remove some loads first. Reset the circuit
breaker by pressing the button again.
Remove some loads and wait until the unit
is cool. Then turn on the unit again.
AVR 1000
1000VA / 600W
220VAC
180 - 264VAC
50Hz
+/-12%
+/-8%
Green lighting
Red lighting
166mm x 161mm x 86.7mm
2.0
Less than 40dB
Solutions
AVR 1200
1200VA / 720W
2.1