11. Dimensions
3 untapped holes for inserting cables in the ATEXcertified ISO M20 cable gland.
(1)
Maximum working range
(2)
4 elongated holes with a 6 mm diameter
(3)
13. Installation and adjustment :
1. Attach the device firmly to a rigid
support
2. Attach the cable supports to rigid
components (thesupports guide the
cable)
3. Fit the recommended end spring
and fix the cable in the spring
4. Remove the cover
.
5. Tension the cable up to the index,
using the turnbuckle or the
incorporated cable tensioner
Standard force
Deflection
Force (daN)
(mm)
260
7
280
8,4
300
9,6
320
10,2
340
12,3
360
13,3
Note : a given force corresponds to a single deflection and a single position
XY2004A12-07
01/12/2016
.
Low force
Deflection
Force (daN)
(mm)
250
4,4
270
4,8
270
5,1
280
5,3
290
6
320
6,6
Operating instructions
Trip wire switch - XY2W series
Came
Index
position
A
1
B
2
C
3
D
4
E
5
F
6
ENG
13/16