6.2 Models for fixed installation
•
Let open cable ends ONLY assemble by experienced
electrician.
•
Cut off power supply before any work on the product,
switch off safety fuse and secure against reconnection.
•
Assure and check the absence of voltage before any
work on the product.
Models without a mated protective contact plug must be permanently instal-
led on the power supply.
The power cables used must have a minimum cross-section of 1.0 mm².
Strands must be provided with wire end ferrules. The following connections
are made at the luster terminal of the product:
1
4
1. Turn off the fuse.
2. Open the connection sleeve by turning it counter-clockwise until the
connection block is released as shown in Fig. 7 - 2.
3.
Insulate the cables as shown in Fig. 7 - 3.
4.
Slide the parts of the connection sleeve shown in Figs. 7 - 4 over the
connection cable.
5.
Screw the power cables as shown in Fig. 7 - 5 using a screwdriver.
6.
Close the connector by turning it clockwise, as shown in Figure 7 - 6.
Risk of electric shock
2
N
L
GND
5
6 mm
15 mm
3
6
Fig. 14: Fixed installation
20