Configuration and connection for the different protocols
Switch SW1 allows to select the short W26 (SW1= OFF) or the long W37 (SW1= ON) format.
In case the short W26 is selected, the content of the frame may be NO FC (SW2= OFF), or include a so called Facility
Code (SW2= ON).
In this case, the value of the Facility Code in Binary is set by 8 switches, each one defining either a 0= OFF or 1= ON.
Remote
Protocol
Power
Control
W26 NO
Facility
+ -
Code
W37
+ -
W26 with
Facility
+ -
Code
*
Facility Code: SW1-8, 0=OFF/1=ON
DEC
BIN
0
00000000
1
00000001
2
00000010
3
00000011
4
00000100
5
00000101
6
00000110
7
00000111
8
00001000
9
00001001
10
00001010
11
00001011
12
00001100
13
00001101
14
00001110
15
00001111
Signal
Output
SW1 SW2
Button
CH1/2/3/4
OFF OFF don't care
1/2/3/4
D0-D1
Button
CH1/2/3/4
ON
1/2/3/4
D0-D1
Button
CH1/2/3/4
OFF ON
1/2/3/4
D0-D1
DEC
BIN
16
00010000
17
00010001
18
00010010
19
00010011
20
00010100
21
00010101
22
00010110
23
00010111
24
00011000
25
00011001
26
00011010
27
00011011
28
00011100
29
00011101
30
00011110
31
00011111
Facility
Code 1 to
8 Bits
EP(1)-Counter(8)-Zeros(2)-Sub(3)-
don't
don't care
DCS(3)-Remote Control Number(19)-
care
mode
EP(1)-Facility Code(8)-Remote Control
Facility
Code
*
DEC
32
00100000
33
00100001
34
00100010
35
00100011
36
00100100
37
00100101
38
00100110
39
00100111
40
00101000
41
00101001
42
00101010
43
00101011
44
00101100
45
00101101
46
00101110
47
00101111
jcmtechnologies
6
FRAME FORMAT
EP(1)-Zeros(4)-Remote Control
Number(20)-OP(1)
OP(1)
Number(16)-OP(1)
BIN
DEC
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
BIN
00110000
00110001
00110010
00110011
00110100
00110101
00110110
00110111
00111000
00111001
00111010
00111011
00111100
00111101
00111110
00111111