This compressor must be electrically grounded. In the event of an electrical short circuit,
grounding reduces the risk of electrical shock by providing an escape wire for electrical
current. This product is equipped with a cord having a grounding wire with an appropriate
grounding plug. The plug must be plugged into an outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DANGER:
IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK
OF ELECTRIC SHOCK. If a repair or replacement cord is necessary, do not connect the
grounding wire to either flat blade terminal. Check with a qualified electrician or serviceman,
if the grounding instructions are not completely understood or if there is doubt as to whether
this product is properly grounded. Do not modify the plug provided. If the supplied plug does
not fit the outlet, have the proper outlet installed by a qualified electrician.
This product is shipped for use on a nominal 120-volt circuit, and has a grounding plug that
looks like the plug in sketch A.
A
Grounding Pin
The motor of this compressor has a thermal overload protector in the motor winding. If the
motor should overheat, the overload protector will shut the motor off. When the temperature
returns to normal, the motor will restart automatically.
NOTICE! Do not stop the compressor by pulling out the plug. Use only the On/Off switch,
which operates a pressure relief valve on the compressor. If the compressor is plugged in
with the switch in the "On" position, the compressor may have trouble restarting against the
high pressure, which could cause excessive heat build up and could damage the motor.
Safety Valve:
This compressor is equipped with a safety valve that is set to avoid over-pressurization of the
air tanks. This valve is factory pre-set at 150 PSI and will not function unless tank pressure
reaches this pressure. DO NOT ATTEMPT TO ADJUST OR ELIMINATE THIS SAFETY DEVICE.
ANY ADJUSTMENTS TO THIS VALVE COULD CAUSE SERIOUS INJURY. If this device
requires service or maintenance, see an Authorized Service Centre.

ELECTRICAL GROUNDING INSTRUCTIONS

14
ELECTRICAL GROUNDING INSTRUCTIONS (continued)

DUTY CYCLE:

To ensure long life of your HAUSSMANN air compressor, do not operate on more than a 50%
duty cycle. If this air compressor pumps air more than 50% of one hour, then its capability is
less than the air delivery required by the application. Always match the air volume
requirements of the attachment or accessory with the air volume delivery of the compressor.
Notice!: The use of extension cords with compressors is not recommended. The use of an
extension cord can result in the loss of voltage supplied to the compressor which could
prevent the compressor from starting. For optimum performance, plug the compressor
directly into an outlet and increase the length of airline as needed.
If an extension cord must be used, use these guidelines:
Distance Needed
Less than 25 ft. (7.6m)
25 - 50 ft. (7.6 - 15m)
Greater than 50 ft. (15m)
C60P
Motor:
Fuse Requirements:
Operating Pressure:
Safety Valve Setting:
Air Delivery:
Maximum Amps at Working Pressure:
Tank Size:
Air Outlet:
Pressure Switch Settings:
Weight
PSI = Pounds Per Square Inch
Recommended Gauge
12 Gauge
10 Gauge
Not Recommended

SPECIFICATIONS

2HP (Peak) / 1.5HP (Running)
115V – 60HZ
15 Amps minimum
0 – 135 PSI
150 PSI
3.7 CFM @ 40 PSI
2.8 CFM @ 90 PSI
11.3
6 Gallons (22.7 L)
1/4" NPT
On @ 105 PSI
Off @ 135 PSI
38 lbs. (17 kg)
CFM = Cubic Feet Per Minute
15