Connect the connection cable B 5940 0300 to the controller B-54900-01-3-9 (see point 2.4) as
indicated by the imprinted colour coding. In doing so, open the terminal clamps up to the lock-in
position and fully insert the cable ends (approx. 10 mm).
Do not strip the insulation off the cable ends!
y
y
A connection is automatically established when closing the connecting terminals.
To take the cable back out, open the connecting terminals beyond the lock-in point. Lever the
cable carefully, e.g. using a precision screwdriver, out of the insulation piercing connecting device.
Cut off the damaged part of the cable before reinserting it into a terminal clamp!
The controller B-54900-01-3-9 is delivered with the jumper inserted. If the controller is operated
without the emergency power backup system B-54903-23-3-9, remove it.
To connect the emergency power backup system B-54903-23-3-9, fully insert the 2-pin connection
cable into the controller and emergency power backup system and make sure the jumper is
inserted.
Fig.4: Connection of emergency power backup system