5320A-LOAD
High Voltage Load Adapter
Avant
INPUT
SENSE
8846A
6-1/2 DIGIT PRECISION MULTIMETER
V
4 W
2W/4W
HI
HI
0.20100
1000 V CAT I
300V
600V CAT II
LO
LO
1V
FUSED
400
BACK
F1
10A
mA
DC V
ACV
REAR
FRONT
RANGE
FREQ
PERIOD
5320A-LOAD
100 mA
10 k
35 k
1200V MAX
2000V MAX
140W MAX
110 W MAX
5520A CALIBRATOR
NORMAL
AUX
SCOPE
V, , ,RTD
A, -SENSE, AUX V
OUT
HI
LO
TRIG
GUARD
20A
20V PK MAX
TC
20V PK MAX
Méthode par tension – vérification des résistances de l'adaptateur de
Valeur de
résistance
Tension de test
nominale
appliquée
extérieurement
à la fréquence
secteur
10 kΩ
200 Vca
35 kΩ
315 Vca
50 kΩ
300 Vca
100 kΩ
600 Vca
250 kΩ
1000 Vca
500 kΩ
1000 Vca
1 MΩ
1000 Vca
5 MΩ
1000 Vca
mA~
F2
F3
F4
F5
MEMORY
INSTR
DC I
AC I
TRIG
SETUP
TEMP
ZERO
MEAS
ANALYZE
SETUP
40 mA
10 mA
50 k
100 k
250 k
500 k
2000V MAX
5500V MAX
5500V MAX
5500V MAX
80 W MAX
300W MAX
120 W MAX
60 W MAX
COM
20 V MAX
PREV
STBY
OPR
EARTH
EXGRD
SCOPE
MENU
µ
dBm
sec
7
8
9
SETUP
RESET
m
V
Hz
n
W
¡F
NEW
4
5
6
CE
k
A
¡C
REF
p
MEAS
MORE
1
2
3
M
F
TC
MODES
MULT
DIV
/ +
0
SHIFT
ENTER
÷
x
Figure 4. Branchements du matériel pour l'autre méthode de test
Tableau 1. Valeurs de vérification des résistances du 5320-LOAD
chargement sous tension
Courant de
test requis par
les
caractéristiqu
es nominales
20 mA
9 mA
6 mA
6 mA
4 mA
2 mA
1 mA
0,2 mA
POWER INPUT
12 V
10 VA MAX.
MAINS SUPPLY
100V/ 120V
220V/ 240V
4 mA
1mA
1M
5 M
5500V MAX
5500V MAX
30 W MAX
6 W MAX
POWER
O
I
EDIT
FIELD
POWER
I
O
Courant
mesuré
Arrière
SAFETY WARNING
READ MANUAL BEFORE USE.
NO USER SERVICEABLE PARTS CONTAINED WITHIN.
HAZARDOUS VOLTAGES PRESENT. DO NOT REMOVE COVERS.
REFER SERVICE TO QUALIFIED PERSONNEL.
DISCONNECT POWER AND SIGNAL LEADS
BEFORE SERVICING.
FLUKE CORPORATION
www.fluke.com
CAUTION
FOR FIRE PROTECTION REPLACE ONLY
FUSE
WITH A 250V FUSE OF INDICATED RATING
T5.0A 250V
(SB)
47 Hz
/ 63 Hz
T2.5A 250V
(SB)
600VA MAX
WARNING:
TO AVOID PHYSICAL INJURY, INSURE THAT THE FILTER
IS PROPERLY INSTALLED BEFORE ENERGIZING INSTRUMENT
CHASSIS
GROUND
WARNING:
TO AVOID ELECTRIC SHOCK GROUNDING
CONNECTOR IN POWER CORD MUST BE CONNECTED
Autre méthode de
vérification avec
Résistance calculée
RL=Vs/Im
(±10 % de la valeur
(±10 % de la valeur
nominale)
DURING USE,
TERMINAL MUST BE
CONNECTED TO THE
PROTECTIVE EARTH
OF THE 5320A
PROTECTIVE
EARTH (GROUND)
NORMAL
ENABLE
INSTALLED
OPTIONS
CALIBRATION
- SC300
- SC600
SERIAL 2
TO UUT
FLUKE CORPORATION
MADE IN USA
PATENTS PENDING
SERIAL 1
FROM HOST
NO INTERNAL USER SERVICEABLE
PARTS. REFER SERVICE TO
QUALIFIED SERVICE PERSONNEL
IEEE-488
10 MHz
IN
OUT
TO CLEAN THE FILTER:
-UNPLUG INSTRUMENT
5V
-REMOVE FILTER
P - P
-FLUSH WITH SOAPY WATER
MAX
-DRY BEFORE REINSTALLATION
fgt104.eps
multimètre
numérique
Résistance
mesurée
nominale)
4