Version/Power Supply H; (Nominal Voltage U N ); Dc/Ac; [Eex Ia] Iic - Camille Bauer SINEAX B 811 Mode D'emploi

Source d'alimentation
Masquer les pouces Voir aussi pour SINEAX B 811:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Non-standard ranges:
0...1 to 0...< 20 mA
resp. live zero
0.2...1 to < (4...20) mA
Open-circuit voltage:
Approx. – 7...+ 22 V
Burden voltage I
:
15 V without communication
A1
10 V (15 V) with communication*
*When a hand-held terminal is connected to the field output
A12, the voltage across the burden at output A1 reduces to
10 V. Digital communication requires a minimum burden at
output A1 of 250 Ω. A 250 Ω resistor is therefore connected
across the output circuit. If the load of the burden across
output A1 already exceeds 250 Ω, the resistor can be
disconnected by changing the position of a jumper. The full
burden voltage of 15 V is then available at output A1 instead
of 10 V.
External resistance I
: R
max. [kΩ] =
A1
ext
I
= Output circuit full-scale value
AN
Burden voltage I
:
< 0.3 V (field indicator)
A12
External
resistance I
:
R
max. [kΩ] =
A12
ext
Residual ripple:
< 1% p.p., DC ... 10 kHz
Response time
(IEC 770):
Approx. 200 ms
Output characteristic: Linear
Power supply H
AC/DC power pack (DC and 45...400 Hz)
Table 1: Nominal voltages and tolerances
Nominal voltage
Tolerance
U
N
24... 60 V
DC / AC
DC – 15...+ 33%
AC ± 15%
85...230 V
1
DC / AC
24... 60 V
DC – 15...+ 33%
DC / AC
AC ± 15%
85...230 V
± 10%
AC
85...110 V
– 15...+ 10%
DC
1
For power supplies > 125 V, the auxiliary circuit should include an
external fuse.
Power input:
Approx. 2.5 W resp. ≤ 3 VA
Communication
Bi-directional communication of digital signals with an "intel-
ligent" two-wire transmitter designed for FSK and a HART or
company-specific protocol.
Frequency range:
500 Hz ... 35 kHz
Input circuit monitor
Pick-up level:
Signalling modes
Output signals
A1 and A12:
15 V (10 V)
I
[mA]
AN
0.3 V
I
[mA]
AN
Frontplate signals:
Output contact AF:
Instrument
version
Table 2: Type of output contact
Standard
(non-Ex)
Type of
protection
"Intrinsically
safe"
Relay approved by UL, CSA, TÜV, SEV

[EEx ia] IIC

Direction of action:
Accuracy data (acc. to DIN/IEC 770)
Basic accuracy:
Environmental conditions
Commissioning
temperature:
– Open-circuit
Input current < 3.6 mA,
adjustable in the works between
1 and 4 mA
– Short-circuit
Input current > 21 mA
adjustable in the works between
20 and 23 mA
– Linear output signal
For an open-circuit output
0 mA (with 4...20 mA)
– 5 mA (with 0...20 mA)
For a short-circuit output
approx. 26 mA
– Increasing output signal
Output approx. 115% of full-scale
value, e.g.
23 mA for output 0/4...20 mA
or
11.5 V for output 0/2...10 V
– Decreasing output signal
(only possible for live zero)
Output approx. 10% of full-scale
value, e.g.
2 mA for output 4...20 mA
or 1 V for output 2...10 V
Failure signalled by red LED
1 relay, 1 potentially-free changeover
contact (see Table 2)
Material
Symbol
Gold flashed
silver alloy
Adjustable by switch
– Relay "energized" or "de-
energized" in the case of a failure
Limit error ≤ ± 0.2%
Including linearity and reproduci-
bility errors
– 10 to + 55 °C
Contact rating
AC: ≤ 2 A / 250 V
(500 VA)
DC: ≤ 1 A / 0.1...250 V
(30 W)
25

Publicité

Table des Matières
loading

Table des Matières