Code
A 202
DE
A 215
7.
Spare parts and accessories
Spare parts:
EN
8.
Technical data
8.1.
Ambient conditions
The recommendations listed below should be complied with as closely as
possible, since they ensure consistent performance by the device coupled
with the minimum requirement for maintenance.
FR
8.2.
Operation
Lifting range:
Temperature:
Duty cycle:
Environment:
Item
IT
92 0051 1500
92 0055 1500
*load evenly distributed
ES
16
Cause
Overheating
Drive overcurrent
obtainable from the Hoffmann Group:
740 mm – 1140 mm
+10 °C to +40°
10% (S3); 1 min ON, 9 min OFF
for use only in dry indoor areas
Troubleshooting
System overload! Disconnect the device from
the mains. If the same error message is still
reported after 10 hours, contact your
customer service.
Continuous full load*
[kg]
350
750
www.hoffmann-group.com
max. load*
[kg]
500
1000