EN
English
MACHINE OPERATION
Read all instructions before using
this machine.
PRE-SWEEP
Sweep the area to be cleaned prior to operating the
machine.
PRE-SPRAY
an approved Hard Surface Pre-Spray detergent. Only use
application. Follow proper mixing and handling instructions on
detergent bottle.
combustible material or work in areas were they may be
present.
SET PRESSURE
While the trigger is activated on the hard surface tool and the
the front of the machine between 400-1200 PSI.
CLEANING WITH HARD SURFACE TOOL
1.
2.
Verify the vacuum hose and solution hose are securely
connected to the machine and hard surface tool.
3.
Choose either the Glide Ring or the Brush Ring for the Hard
Surface Tool. Using the 3 tabs snap the desired ring onto
the Dome Housing of the Hard Surface Tool.
Glide Ring – man made tiles such as porcelain and ceramic.
Brush Ring – natural stone and non-man made surfaces with a
texture.
Glide Ring
8
Brush Ring
4.
Ensure the vacuum break cover is closed when using the
Hard Surface Tool. If the Hard Surface Tool happens to
vacuum break cover up. Once the Hard Surface Tool is loose
5.
Turn on the pump and vacuum switches. Turn on the Auto-
Dump switch if using this feature.
Vacuum
Switch
6.
For optimum cleaning results pull trigger while moving the
Hard Surface Tool in a front to back motion.
7.
moving to the next area.
NOTE: Use defoamer any time foaming occurs in the recovery
tank to prevent damage to the motor or other components.
8.
Monitor the water level in the solution tank. If the solution
tank runs dry, the pump must be reprimed.
9.
When the solution tank is low, turn off all the switches,
may not work if there is too much foam in the tank. Always use
10.
disconnecting solution hose relieve the water pressure from
the Hard Surface Tool by holding the trigger on the Hard
Surface Tool.
Vacuum
Break Cover
Auto Dump
Switch
Pump Switch