PREPARATION OF
EQUIPMENT
Control filter systems
-
Release the lever (1a/1 Fig.1) and re-
move the cover (2 Fig.2) completely,
along with the fleece filter bag (3 Fig.2).
-
Remove the cloth dust bag (4 Fig. 3) and
check that the cartridge filter (5 Fig. 4) is
mounted inside the unit.
-
Replace the filter cloth (4 Fig.3), replace
the paper bag (3 Fig.5) on the cover (2
Fig.5) and keeping it in position refit the
cover (2 Fig.6).
-
Lock the lid by the handle (1a/1 Fig.1)
NOTE:
The cover can be mounted with the output of
the tube left or right according to the needs
of the user.
Assembling of pipes
-
Insert the sleeve (8 Fig.7) hose supplied
in the air intake hole (9 Fig.7).
-
Attach the rigid extensions to the ergo-
nomic handle (10 Fig.8) of the hose (11
Fig.8).
-
Attach to the rigid extension (11 Fig.9)
the wanted accessory (suction nozzle,
dusting brush, crevice tool, etc. ..)
Placing electric cable
(for 230 V model)
-
Form a ring with the with the electric ca-
ble and attach it to the support (12 Fig.10)
positioning it as shown in figure 10.
All manuals and user guides at all-guides.com
Before recharging the batteries
(for Model 24 V)
Remove the charger and the battery from the
pack.
-
-
After connecting the power cable (15 Fig. 11)
before connecting the cable (13 Fig.11) to
the battery (14 Fig. 11) the charger WON'T
WORK.
-
-
Do not leave the cable (13 Fig. 11) con-
nected to the battery with the network cable
disconnected from the charger; the batteries
may discharge and could be damaged.
Installing the batteries
(for 24V model)
-
-
-
-
EN - 7
Plug the cable (13 Fig.11) to the battery
(14 Fig.11).
Connect the charger to the socket.
(15 Fig.11).
NOTE:
On the charger (15 Fig. 11) the „green"
led will blink twice (16 Fig. 11) indicating
proper functioning;; then, the red led will
turn on (17 Fig. 11) or the yellow one (18
Fig. 11) depending on the battery's condi-
tion.
When the charger light turns greeb (16
Fig. 11) the batteries are charged.
NOTE:
Check if the switch (27 Fig.16) is on posi-
tion "0".
Place the battery (14 Fig. 12) on the de-
vice by inserting the contacts (19 Fig. 12)
in the wholes (20 Fig. 12).
Press the battery (14 Fig. 13) down until
you here a coupling „CLICK".
Make sure that the lever (6 Fig. 13) is fa-
cing down and that in the slot (7 fig. 13)
appears the green color indicating the
correct
coupling.
EN