COFFEE SYSTEMS
IMPORTANT INSTRUCTIONS
WARNING
•
Check that the main power supply voltage corresponds to
the value indicated on the rating plate on the side of the
appliance.
•
If the power socket does not match the plug on the appli-
ance, have the socket replaced with a suitable type by a
qualified professional.
•
Do not use multiple sockets or extensions.
CAUTION
Safety cutout devices must be included in the main power
supply in compliance with the installation regulations in the
country concerned.
SPECIFICATIONS
Installation Requirements
The coffee system can be installed in a standard or flush
inset application. A minimum base support of 45 kg is
required. The sides of the cabinetry opening must be
adequate to support installation of the mounting slides.
Finish the edges of the opening. They may be visible when
the unit is slid forward.
The unit has face trim on the top, bottom and both sides
that will overlap stiles and rails. Refer to the chart below for
trim overlaps. For flush inset installations, a minimum 3 mm
reveal is required on all four sides. To ensure consistent 3
mm reveals, each corner of the opening must be exactly
90°.
The Wolf coffee system is designed and agency approved
for installation with Wolf cooktops, built-in ovens, micro-
waves and warming drawers only.
TRIM OVERLAP
OVERLAP
Top
Bottom
Sides
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
page 4. A separate circuit, servicing only this appliance is
required. A ground fault circuit interrupter (GFCI) is not rec-
ommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Power Cord
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
5 mm
disconnection must be provided for all poles of the power
0 mm
supply. When switched off there must be an all pole contact
18 mm
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
wolfappliance.com
220-240 VAC, 50/60 Hz
5.6 amps
1.8 m
|
3